Product Features
Solid state microprocessor with LED display. Time of day, remaining capacity, regeneration cycle in process
Compact turbine meter
Downflow or upflow regeneration cycles
NOVRAM valve status and memory backup
Continuous flow rate of 20 GPM
Backwash capacity handles tanks up to 12" diameter for softener applications, 10" for filter applications
Double backwash capability
Valve Specifications
Valve material Noryl®*
Inlet/Outlet - 3/4", 1", 1-1/4" NPTF
Cycles - 5
Flow Rates (50 psi Inlet) - Valve Alone
Continuous (15 psi drop) 20 GPM
Peak (25 psi drop) 26 GPM
CV (flow at 1 psi drop) 5.0
Max. backwash (25 psi drop) 7 GPM
Regeneration
Downflow/Upflow - Both
Adjustable cycles - Yes
Time available Up to 99 minutes per cycle
Meter Information
Meter accuracy range - .25 - 15 GPM ± 5%
Meter capacity range (gal.) - 1 - 9,999
Dimensions
Distributor pilot - 0.8125" or 1.05" pipe O.D.
Drain line - 1/2" NPTF
Brine line - 1600 - 3/8"
Drain line - 2-1/2" - 8 NPSM
Height from top of tank - 7-1/2"
Typical Applications
Water softener - 6"-12" diameter
Iron filter - 6"-10" diameter
Sediment filter - 6"-10" diameter
Carbon filter - 6"-10" diameter
Neutralizing filter - 6"-10" diameter
Additional Information
Injector brine system - 1600
Electrical rating - 24v, 110v, 220v - 50 Hz, 60 Hz
Max. - VA 8.4
Estimated shipping weight Time clock: 6 lbs.
Metered valve: - 7 lbs.
Pressure Hydrostatic: - 300 psi
Working: - 20 - 125 psi
Temperature - 34° - 110° F
Approvals
WQA Gold Seal system 0.5 - 2.0 cu. ft.
UL (power head only)